DTC C001D:01/C001D:49 [DSC HU/CM]


id040262845900

DTC
C001D:01
RR outlet solenoid valve
C001D:49
DETECTION CONDITION
•  RR outlet solenoid valve malfunction is detected.
FAIL-SAFE FUNCTION
•  Refer to “Fail-safe function table”. (See DTC TABLE [DSC HU/CM].)
POSSIBLE CAUSE
•  RR outlet solenoid valve malfunction
SYSTEM WIRING DIAGRAM


Diagnostic Procedure

Step

Inspection

Action

1
VERIFY RR OUTLET SOLENOID VALVE OPERATION
•  Using the M-MDS, perform the simulation inspection for RR outlet solenoid valve.
•  Does the solenoid valve operate?
Yes
Go to the next step.
No
Replace the DSC HU/CM, then go to the next step.
2
VERIFY DTC TROUBLESHOOTING COMPLETED
•  Using the M-MDS, clear the DTC from the DSC HU/CM.
•  Using the M-MDS, perform the DSC HU/CM DTC inspection.
•  Is the same Pending DTC present?
Yes
Repeat the inspection from Step1.
If the malfunction recurs, replace the DSC HU/CM, then go to the next step.
No
Go to the next step.
3
VERIFY NO DTC IS PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.