REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]
id0740a2817400
1. Install the manifold gauge. (See MANIFOLD GAUGE SET CONNECTION.)
2. Verify the high-pressure side reading of the manifold gauge.
3. Measure the terminal voltage at PCM terminal 2AZ, 2AV and 2AI.
4. Using the graph below, measure and verify the terminal voltages at 2AV.
5. Follow the PCM inspection when measuring the other terminal voltages. (See PCM INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0].)
amxzzw00005395
|