BLIND SPOT MONITORING (BSM) WARNING BUZZER IS NOT ACTIVATED [BLIND SPOT MONITORING (BSM) SYSTEM]
id1503a3020600
Description
Possible malfunction
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY PERSONALIZATION FEATURE SETTING
• Verify the volume setting of the blind spot monitoring (BSM) warning buzzer of the personalization features.
• Is the volume setting off?
|
Yes
|
Perform the volume setting of the blind spot monitoring (BSM) warning buzzer in consultation with the customer.
|
No
|
Go to the next step.
|
||
2
|
DETERMINE IF MALFUNCTION CAUSE IS BUZZER SOUND RELATED CIRCUIT
• Implement the instrument cluster simulation ALARM using the M-MDS, and activate the warning alarm.
• Is the warning alarm activated?
|
Yes
|
Go to the next step.
|
No
|
Replace the instrument cluster.
|
||
3
|
DETERMINE IF MALFUNCTION CAUSE IS BLIND SPOT MONITORING (BSM) CONTROL MODULE
• Implement the blind spot monitoring (BSM) system simulation Buzzer item using the M-MDS.
• Does the blind spot monitoring (BSM) warning buzzer activate?
|
Yes
|
Go to the symptom troubleshooting procedure, "Blind spot monitoring (BSM) warning indicator light falsely flashes.
|
No
|
Replace the blind spot monitoring (BSM) control module (LH).
|