FUEL PUMP UNIT INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0]
id0114zg801100
Continuity Inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
2. Remove the service hole cover. (See FUEL TANK REMOVAL/INSTALLATION [SKYACTIV-G 1.5, SKYACTIV-G 2.0].)
3. Disconnect the fuel pump unit connector. (See FUEL PUMP UNIT REMOVAL/INSTALLATION [SKYACTIV-G 1.5, SKYACTIV-G 2.0].)
4. Inspect for continuity between fuel pump unit terminals A—B.
am2zzw00012350
|