i-stop WARNING ALARM [SKYACTIV-G 1.5, SKYACTIV-G 2.0]
id0140g8300500
Purpose
Function
ac3wzn00000691
|
Construction
Operation
1. The instrument cluster receives (1) the i-stop warning alarm request signal from the PCM.
2. The instrument cluster turns the transistor on (2) based on the i-stop warning alarm request signal.
3. When the transistor turns on, a ground circuit with the i-stop warning alarm is established and the i-stop warning alarm sounds (3).
ac3wzn00000692
|
Fail-safe