SIMULATION TABLE [EVP CONTROL UNIT]
id040251837600
Simulation item |
Operation |
Output part |
Operating condition |
---|---|---|---|
VPS_FBK
|
Off/On
|
Electric vacuum pump
|
For maximum of 30 s when all of the following conditions are met with ignition switched ON (engine off or on)
• Vehicle speed 6 km/h {3 mph} or less
• Operation of electric vacuum pump not inhibited by fail-safe
|