NOT P POSITION SWITCH INSPECTION


id051400260500

Note
•  The not P position switch is built into the selector lever component.

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)

2.  Remove the following parts:

(1)  Selector lever knob (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)
(2)  Shift panel component (See SHIFT PANEL REMOVAL/INSTALLATION.)

3.  Disconnect the selector lever component connector.

amxuuw00002843

4.  Verify that the continuity between selector lever component terminals B and G.

adejjw00010793

•  If not as verified, replace the selector lever component. (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)

Not P position switch specification

Test condition

Continuity

Selector lever is in the P position.
No continuity
Selector lever is not in the P position.
Continuity