DTC TABLE [INSTRUMENT CLUSTER]
id0902e8960500
DTC No. |
Warning/indicator light |
Description |
Fail-safe |
Drive cycle |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|
C0077:00*2
|
|||||||
C2011:49*2
|
|||||||
C2011:87*2
|
|||||||
C2012:49*2
|
|||||||
C2012:87*2
|
|||||||
C2013:49*2
|
|||||||
C2013:87*2
|
|||||||
C2014:49*2
|
|||||||
C2014:87*2
|
|||||||
U0001:88
|
—
|
Module communication error (HS-CAN)
|
—
|
—
|
C, D
|
×
|
|
U0010:88
|
—
|
Module communication error (MS-CAN)
|
—
|
—
|
C, D
|
×
|
|
U0100:00
|
Illuminated/Flash
|
Communication error with PCM
|
—
|
—
|
C, D
|
×
|
|
U0101:00*3
|
—
|
Communication error with TCM
|
—
|
—
|
C, D
|
×
|
|
U0121:00
|
Illuminated/Flash
|
Communication error with DSC HU/CM
|
—
|
—
|
C, D
|
×
|
|
U0127:00*2
|
|||||||
U012B:00
|
—
|
Communication error with EVP (electric vacuum pump) control unit
|
—
|
—
|
C, D
|
—
|
|
U0131:00
|
Illuminated/Flash
|
Communication error with electric power steering (EPS) control module
|
—
|
—
|
C, D
|
×
|
|
U0140:00
|
Illuminated/Flash
|
Communication error with BCM
|
—
|
—
|
C, D
|
×
|
|
U0151:00
|
Illuminated/Flash
|
Communication error with SAS control module
|
—
|
—
|
C, D
|
×
|
|
U0156:00*4
|
Illuminated/Flash
|
Communication error with connectivity master unit (CMU)
|
—
|
—
|
C, D
|
×
|
|
U0182:00
|
Illuminated/Flash
|
Communication error with auto leveling control module or adaptive front lighting system (AFS) control module
|
—
|
—
|
C, D
|
×
|
|
U0207:00*8
|
—
|
Communication error with retractable hardtop control module
|
—
|
—
|
C, D
|
×
|
|
U0214:00
|
Illuminated/Flash
|
Communication error with start stop unit
|
—
|
—
|
C, D
|
×
|
|
U0232:00*5
|
Illuminated/Flash
|
Communication error with blind spot monitoring (BSM) control module (LH)
|
—
|
—
|
C, D
|
×
|
|
U023A:00*6
|
Illuminated/Flash
|
Communication error with forward sensing camera (FSC)
|
—
|
—
|
C, D
|
×
|
|
U0298:00*7
|
—
|
Communication error with DC-DC converter (i-ELOOP)
|
—
|
—
|
C, D
|
—
|
|
U0300:00
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U0401:68
|
Illuminated/Flash
|
Error signal received from PCM
|
—
|
—
|
C, D
|
×
|
|
U0402:68*3
|
—
|
Error signal received from TCM
|
—
|
—
|
C, D
|
×
|
|
U0422:68
|
Illuminated/Flash
|
Error signal received from BCM
|
—
|
—
|
C, D
|
×
|
|
U0515:68
|
Illuminated/Flash
|
Error signal received from start stop unit
|
—
|
—
|
C, D
|
×
|
|
U0533:68*5
|
—
|
Error signal received from blind spot monitoring (BSM) control module (LH)
|
—
|
—
|
C, D
|
—
|
|
U053B:00*6
|
Illuminated/Flash
|
Error signal received from forward sensing camera (FSC)
|
—
|
—
|
C, D
|
×
|
|
U2005:86
|
—
|
Error signal received from PCM
|
—
|
—
|
C, D
|
×
|
|
U2013:13
|
—
|
Cluster switch circuit malfunction
|
—
|
—
|
C, D
|
×
|
|
U2100:00
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U2105:02*3
|
—
|
Drive selection switch circuit malfunction
|
—
|
—
|
C, D
|
—
|
|
U2300:41
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U2300:51
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U2300:56
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U2300:57
|
—
|
Instrument cluster configuration error
|
—
|
—
|
C, D
|
×
|
|
U3000:41
|
—
|
Instrument cluster internal malfunction
|
—
|
—
|
C, D
|
×
|
|
U3000:42*2
|
|||||||
U3003:16
|
—
|
Low power supply voltage input to instrument cluster
|
—
|
—
|
C, D
|
×
|