AFTER SERVICE PRECAUTION [L8, LF]
id0114a3801900
Fuel Leakage Inspection
Using M-MDS
1. Connect the M-MDS to the DLC-2.
amxzzw00000826
|
2. Start the fuel pump using the “FP” simulation function. (See ON-BOARD DIAGNOSTIC TEST [L8, LF].)
3. Verify that there is no fuel leakage from the pressurized parts.
4. In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.
Without using M-MDS
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)
3. Short the check connector terminal F/P to ground using a jumper wire.
amxzzw00000827
|
amxzzw00000828
|
4. Connect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)
5. Turn the ignition switch to the ON position to operate the fuel pump.
6. Verify that there is no fuel leakage from the pressurized parts.
7. In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.