EVAPORATIVE PURGE CONTROL OPERATION [L8, LF]
id0140i7171900
Determination of Purge Solenoid Valve Energization Time
Calculation Method for Purge Flow Amount
Contents |
Calculation or determination method of purge flow amount and correction |
|
---|---|---|
Basic purge flow amount
|
The basic purge flow amount is determined by multiplying the intake air temperature correction to the purge mass volume which is calculated by multiplying the base purge rate and the intake air mass volume, which differs according to engine conditions.
|
|
Correction
|
Purge startup correction
|
Purpose: Prevents a sudden change in air/fuel ratio during the startup of purge control.
During purge control startup
• When purge control operation conditions are met→correction
|
Volume decrease correction
|
Purpose: Decreases the amount of purge flow and stabilize the air/fuel ratio.
When the fuel injection control feedback correction value is unstable
• According to the A/F sensor feedback condition
|
Operation Conditions