BAROMETRIC PRESSURE (BARO) SENSOR CONSTRUCTION/OPERATION [L8, LF]
id0140i7172900
• Integrated in the PCM.
• The piezoelectric element is enclosed in the sensor and the electric potential difference changes as the BARO drops. The output voltage decreases as the BARO decreases.