TURBINE SENSOR REMOVAL/INSTALLATION [SJ6A-EL]


id051311252000

Caution
•  Water or foreign material entering the connector can cause poor connections or corrosion. Be sure that water or foreign material do not enter the connector when disconnecting it.
•  Do not damage the turbine sensor.

1.  Remove the battery cover.

2.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)

3.  Disconnect the turbine sensor connector.

4.  Remove the turbine sensor.

e5u513zw5070

5.  Install the turbine sensor.

Tightening torque
3.9—6.9 N·m {40—70 kgf·cm, 35—60 in·lbf}

6.  Connect the turbine sensor connector.

7.  Connect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)

8.  Install the battery cover.