NO.1 INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [FULL-AUTO AIR CONDITIONER]
id0703c1800400
1
|
Insufficient air (or no air) blown from vents.
|
DESCRIPTION
|
• Problem with each vent and/or duct.
• Airflow mode does not change.
|
POSSIBLE CAUSE
|
• Malfunction in airflow mode actuator
• Malfunction in VENT mode system
• Malfunction in HEAT mode system
• Malfunction in DEFROSTER mode system
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT AIRFLOW MODE ACTUATOR
• Inspect airflow mode actuator.
• Is it okay?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace malfunctioning part in accordance with further inspection result.
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN VENT MODE OR OTHER MODES
• Does air blow out when in VENT mode?
|
Yes
|
Go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT DUCT IN DASHBOARD IS INSTALLED
• Is duct in dashboard properly installed?
|
Yes
|
Inspect duct for clogging, deformity and air leakage, then go to Step 9.
|
No
|
Install duct securely in the proper position, then go to Step 9.
|
||
5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN HEAT MODE OR DEFROSTER MODE
• Does air blow out when in HEAT mode?
|
Yes
|
Go to the next step.
|
No
|
Inspect vent for clogging, then go to Step 9.
|
||
6
|
INSPECT DEFROSTER MODE
• Does air blow out when in DEFROSTER mode?
|
Yes
|
Operation is okay. Recheck malfunction symptoms.
|
No
|
Go to the next step.
|
||
7
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
8
|
VERIFY THAT DEFROSTER DUCT IS INSTALLED
• Is defroster duct properly installed?
|
Yes
|
Inspect duct for clogging, deformity, and air leakage, then go to the next step.
|
No
|
Install duct securely in proper position, then go to the next step.
|
||
9
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|