NO.3 AIR INTAKE MODE DOES NOT CHANGE [MANUAL AIR CONDITIONER]
id0703c2802900
3
|
Air intake mode does not change.
|
DESCRIPTION
|
• Air intake mode does not change when switching REC/FRESH mode.
|
POSSIBLE CAUSE
|
• Malfunction in air intake actuator
• Malfunction in air intake door
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR INTAKE ACTUATOR, WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
• Switch the ignition to ON.
• Test voltages at the following terminals of climate control unit.
• Are voltages okay?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 3.
|
||
2*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR INTAKE ACTUATOR OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR)
• Test voltages at the following terminals of air intake actuator.
• Are voltages as shown below?
|
Yes
|
Replace air intake actuator, then go to Step 8.
|
No
|
Repair wiring harness between climate control unit and air intake actuator, then go to Step 8.
|
||
3
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN AIR INTAKE ACTUATOR OR ELSEWHERE
• Disconnect air intake actuator connector.
• Test voltages at the following terminals of climate control unit.
• Are voltages okay?
|
Yes
|
Inspect air intake actuator, then go to Step 8.
|
No
|
Go to the next step.
|
||
4
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
• Disconnect climate control unit connector.
• Test voltages at the following terminals of climate control unit.
• Are voltages approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between climate control unit and air intake actuator, then go to Step 8.
|
||
5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
• Switch the ignition to off.
• Inspect for continuity at the following terminals between climate control unit and ground.
• Is there continuity?
|
Yes
|
Repair wiring harness between climate control unit and air intake actuator, then go to Step 8.
|
No
|
Go to the next step.
|
||
6
|
INSPECT AIR INTAKE LINK
• Inspect air intake links.
• Are above items okay?
|
Yes
|
Go to the next step.
|
No
|
Apply grease to links. If any links are damaged, replace air intake actuator, then go to Step 8.
|
||
7
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR INTAKE DOOR
• Inspect blower unit air intake door.
• Are above items okay?
|
Yes
|
Replace climate control unit, then go to the next step.
|
No
|
Remove obstruction, or install doors in proper position. If any doors are cracked or damaged, replace them, then go to the next step.
|
||
8
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does air intake mode change smoothly?
|
Yes
|
Troubleshooting completed. Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|