DTC B1317/B1318 [POWER RETRACTABLE HARDTOP]
id0902j2350700
DTC |
B1317 |
Battery power supply voltage increases (17.5 V or more) |
---|---|---|
B1318 |
Battery power supply voltage decreases (less than 7.5 V) |
|
DETECTION CONDITION
|
• If the power retractable hardtop control module power supply voltage is not within 7.5—17.5 V.
|
|
POSSIBLE CAUSE
|
• ROOM 15 A fuse malfunction
• Battery malfunction
• Open or short circuit in wiring harness between battery and power retractable hardtop control module
• Power retractable hardtop control module malfunction
|
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT THE FUSE
• Remove the ROOM 15 A fuse.
• Is the fuse normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the fuse.
|
||
2
|
INSPECT THE BATTERY
• Measure the battery positive voltage.
• Is the voltage 8.5 V—16.5 V?
|
Yes
|
Go to the next step.
|
No
|
The battery has a malfunction. Inspect the charge/discharge system.
|
||
3
|
INSPECT WIRING HARNESS BETWEEN BATTERY AND POWER RETRACTABLE HARDTOP CONTROL MODULE
• Turn the ignition switch to the ON position.
• Measure the power retractable hardtop control module terminal 1X voltage.
• Is the voltage 8.5 V—16.5 V?
|
Yes
|
Replace the power retractable hardtop control module.
|
No
|
DTC troubleshooting completed.
|