INSTRUMENT CLUSTER CONFIGURATION


id092200496200

1.  Connect the M-MDS to the DLC-2.

amxzzw00001703

2.  After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

•  When using the IDS (laptop PC)
1.  Select “Module Programming”.
•  When using the PDS (Pocket PC)
1.  Select “Programming”.
2.  Select “Module Programming”.

3.  Select “Programmable Module Installation”.

4.  Select “IC” and perform procedures according to directions on the M-MDS screen.

5.  Retrieve DTCs using the M-MDS and verify that there is no DTC present.

•  If any DTC is present, perform applicable DTC inspection. (See DTC INSPECTION [INSTRUMENT CLUSTER].)