OIL CONTROL VALVE (OCV) INSPECTION [ZJ, ZY]
id0110b7801400
Coil resistance inspection
1. Disconnect the negative battery cable.
2. Disconnect the OCV connector.
3. Measure the coil resistance between terminals A and B using a tester.
am2zzw00004924
|
4. Connect the OCV connector.
Spool Valve Operation Inspection
1. Disconnect the negative battery cable.
2. Remove the OCV. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION [ZJ, ZY].)
3. Verify that the spool valve inside the OCV is at the maximum valve timing retard position as shown in the figure.
am2zzw00001667
|
4. Verify that the battery is fully charged. (See BATTERY INSPECTION [ZJ, ZY].)
5. Apply battery positive voltage between oil control valve terminals A and B, and verify that the spool valve operates and moves to the maximum valve timing advance position.
am2zzw00004924
|
6. Stop applying battery positive voltage and verify that the spool valve returns to the maximum valve timing retard position.
am2zzw00001668
|
7. Install the OCV. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION [ZJ, ZY].)