VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR INSPECTION [ZJ, ZY]


id0113a8804700


With Variable Intake Air System


Operation inspection

1.  Disconnect the negative battery cable.

2.  Remove the variable intake air shutter valve actuator. (See VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR REMOVAL/INSTALLATION [ZJ, ZY].)

3.  Connect the battery positive voltage to terminal A or B, and verify that the gear moves.

am2zzw00001398

•  If there is any malfunction, replace the variable intake air shutter valve actuator. (See VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR REMOVAL/INSTALLATION [ZJ, ZY].)

Terminal

Gear rotation direction

A

B

B+
Ground
Counterclockwise
Ground
B+
Clockwise