CURRENT SENSOR CONSTRUCTION/OPERATION [ZJ, ZY]


id0140c4184100


With Current Sensor

•  Installed on the battery.
am2zzn00001253
•  The hall element design has been adopted for the sensor.
•  Voltage is output based on the electrical current flowing to the negative battery cable.

Current sensor characteristic

am2zzn00001254