TORQUE CONVERTER CLEANING
id051700661500
Cleaning Outside of Torque Converter
1. Plug to the position shown in the figure with packing tape.
azzjjw00001502
|
2. Wipe off foreign matter on the exterior of the torque converter using a cloth.Depending on the condition, clean using detergent and dry using compressed air.
3. Throw away the used packing tape used as the plug.
azzjjw00001503
|
Torque Converter Flushing
1. Prepare a clean oil receptacle.
azzjjw00001062
|
2. Add new ATF (ATF FZ) to the torque converter from the position shown in the figure.
azzjjw00001063
|
3. Shake the torque converter to stir the ATF in the torque converter.
azzjjw00001064
|
4. Drain the ATF in the torque converter into the clean oil receptacle.
azzjjw00001065
|
5. Verify that none of the following foreign matter is mixed in with the ATF drained from the torque converter:
6. Dispose of the ATF in the oil receptacle and clean the oil receptacle.
7. Perform Steps 2 — 6 three times.