ON-BOARD DIAGNOSTIC [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]
id0702k3126600
Outline
Block Diagram
am2zzn00003516
|
Function
Malfunction detection function
Memory function
Malfunction indication function
DTC table
DTC No. |
Warning/indicator light |
System malfunction location |
Fail-safe function |
Drive cycle |
Self test type*1 |
Memory function |
---|---|---|---|---|---|---|
B10FB:71*2
|
—
|
Air intake actuator motor lock
|
X
|
—
|
C
|
X
|
B11F0:12*2
|
—
|
Air intake actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
B11F0:13*2
|
—
|
Air intake actuator (potentiometer) circuit open
|
X
|
—
|
C, D
|
X
|
B11F5:86*2
|
—
|
Invalid data (humidity sensor temperature) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
B1A69:86*2
|
—
|
Invalid data (relative humidity) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
B1B71:11
|
—
|
Evaporator temperature sensor circuit short to ground
|
X
|
—
|
C, D
|
X
|
B1B71:13
|
—
|
Evaporator temperature sensor circuit open
|
X
|
—
|
C, D
|
X
|
U0010:88
|
—
|
Unit communication error (MS-CAN)
|
—
|
—
|
C
|
X
|
U0155:00
|
—
|
Communication error with instrument cluster
|
X
|
—
|
C, D
|
X
|
U0423:68
|
—
|
Invalid date received from Instrument cluster
|
X
|
—
|
C, D
|
X
|
U200D:11
|
—
|
Climate control unit circuit voltage (+5V) circuit short to ground
|
—
|
—
|
C, D
|
X
|
U210A:86*2
|
—
|
Invalid data (windshield temperature) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
U2300:54
|
—
|
Configuration error (data not received)
|
X
|
—
|
C, D
|
X
|
U2300:55
|
—
|
Configuration error (not configured)
|
X
|
—
|
C, D
|
—
|
U2300:56
|
—
|
Configuration error (ineffective/non-interchangeable data read)
|
X
|
—
|
C, D
|
X
|
U2300:64
|
—
|
Configuration error (error value read)
|
X
|
—
|
C, D
|
X
|
U3003:16
|
—
|
Climate control unit power supply circuit voltage below threshold (10.00 V or less)
|
—
|
—
|
C, D
|
X
|
U3003:17
|
—
|
Climate control unit power supply circuit voltage above threshold (17.30 V or more)
|
—
|
—
|
C, D
|
X
|
U300E:13
|
—
|
Climate control unit power supply circuit open (IG1)
|
—
|
—
|
C, D
|
X
|
ac5wzn00001320
|
ac5wzn00001326
|
PID/data monitor
PID/data monitor table
PID |
Unit/Condition |
Data contents |
Climate control unit terminal |
---|---|---|---|
A/C_SW
|
Off/On
|
• Off: A/C switch is off.
• On: A/C switch is on.
|
—
|
B_MT_RLY_CS
|
Off/On
|
• Off: Blower relay is off.
• On: Blower relay is on.
|
—
|
ELE_W/P
|
|
||
ENG_C_TMP
|
°C, °F
|
Engine coolant temperature is displayed.
|
—
|
EVA_TMP_SEN
|
°C, °F
|
Evaporator temperature is displayed.
|
G, J
|
F_REC_CS
|
Off/On
|
• Off: Forced recirculate control is off.
• On: Forced recirculate control is on.
|
—
|
F_WIND_TEMP
|
°C, °F
|
Windshield temperature is displayed.
|
—
|
HUMIDITY_SEN
|
%
|
Relative humidity is displayed.
|
—
|
OUT_CAR_TMP
|
°C, °F
|
Ambient temperature is displayed.
|
—
|
R/DEF_CS
|
Off (enable)/
Off (suspend)/
Off (inhibit)/
On
|
• Off (enable): Rear window defogger is off (operation enabled).
• Off (suspend): Rear window defogger is off (operation interrupted / indicator is kept On).
• Off (inhibit): Rear window defogger is off (operation disabled / indicator is turned Off).
• On: Rear window defogger is on.
|
—
|
R/DEF_SW
|
Off/On
|
• Off: Rear window defogger switch is off.
• On: Rear window defogger switch is on.
|
—
|
REC_SW
|
Off/On
|
• Off: RECIRCULATE switch is off.
• On: RECIRCULATE switch is on.
|
—
|
RLS_TEMP
|
°C, °F
|
Humidity sensor temperature is displayed.
|
—
|
STOP_ST
|
Available/
Not Available/
Error
|
• i-stop permit condition: Available
• i-stop inhibit condition: Not Available
• i-stop signal failure: Error
|
—
|