THERMOSTAT INSPECTION [ZY]
id0112008013a5
-
Warning
-
• During inspection, the thermostat and water are extremely hot and they can cause severe burns. Do not touch the thermostat and water directly.
1. Inspect the following.
-
• A closed valve at room temperature
-
• The opening temperature and lift of the valve
-
- If there is any malfunction, replace the thermostat.
Thermostat initial-opening temperature
-
80-84 °C {176-183 °F}
Thermostat full-open temperature
-
95 °C {203 °F}
Thermostat full-open lift
-
8.5 mm {0.33 in} or more