SIMULATION FUNCTION [FN4A-EL]


id0502a1100800

• By using the WDS or equivalent, simulation items for input/output parts preset in the PCM can be optionally selected and operated regardless of PCM control conditions.

Simulation Item Table

X: Available

Simulation item

Applicable component

Unit/Condition

Operation

PCM terminal

IG ON

Idle

LPS
Pressure control solenoid control signal in PCM
%
 
X
1P, 1T
SSA/SS1
Shift solenoid A control signal in PCM
%
 
X
1D
SSB/SS2
Shift solenoid B control signal in PCM
%
 
X
1H
SSC/SS3
Shift solenoid C control signal in PCM
%
 
X
1L
SSD/SS4
Shift solenoid D control signal in PCM
On/Off
 
X
1K
SSE_SS5
Shift solenoid E control signal in PCM
On/Off
 
X
1O