PID name (Definition)
|
Unit/State
|
Detection state
|
SAS control module terminal
|
CCNT_RCM
(Number of continuous DTCs)
|
-
|
• DTC is detected: 1-255
• DTC is not detected: 0
|
-
|
D_CRSH_S
(Driver-side side air bag sensor state)
|
OK/
COMM FAIL/
INT FAIL
|
• Sensor normal: OK
• Sensor communication error: COMM FAIL
• Sensor internal circuit abnormal: INT FAIL
|
1S, 1R
|
D_PTENSFLT
(Driver-side pre-tensioner seat belt circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1E, 1I
|
DS_AB_ST
(Driver-side side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1M, 1Q
|
DS_CURT_ST
(Driver-side curtain air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1C, 1G
|
DSB_P_ST
(Driver-side pre-tensioner seat belt circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1E, 1I
|
DS1_STAT
(Driver-side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
2J, 2N
|
OD_D_CRSH
(On demand driver-side side air bag sensor state)
|
OK/
COMM FAIL/
INT FAIL
|
• Sensor normal: OK
• Sensor communication error: COMM FAIL
• Sensor internal circuit abnormal: INT FAIL
|
1R, 1S
|
OD_D_CURT
(On demand driver-side curtain air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1C, 1G
|
OD_DAB1_ST
(On demand driver-side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
2J, 2N
|
OD_DSAB_ST
(On demand driver-side side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1M, 1Q
|
OD_F_CRSH
(On demand crash zone sensor state)
|
OK/
COMM FAIL/
INT FAIL
|
• Sensor normal: OK
• Sensor communication error: COMM FAIL
• Sensor internal circuit abnormal: INT FAIL
|
1J, 1K
|
OD_P_CRSH
(On demand passenger-side side air bag sensor state)
|
OK/
COMM FAIL/
INT FAIL
|
• Sensor normal: OK
• Sensor communication error: COMM FAIL
• Sensor internal circuit abnormal: INT FAIL
|
1N, 1O
|
OD_P_CURT
(On demand passenger-side curtain air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1D, 1H
|
OD_PAB1_ST
(On demand passenger-side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
2R, 2V
|
OD_PSAB_ST
(On demand passenger-side side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1P, 1T
|
P_CRSH_S
(Passenger-side side air bag sensor state)
|
OK/
COMM FAIL/
INT FAIL
|
• Sensor normal: OK
• Sensor communication error: COMM FAIL
• Sensor internal circuit abnormal: INT FAIL
|
1N, 1O
|
P_PTESFLT
(Passenger-side pre-tensioner seat belt circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1A, 1B
|
PS_AB_ST
(Passenger-side side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1P, 1T
|
PS_CURT_ST
(Passenger-side curtain air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1D, 1H
|
PSB_P_ST
(Passenger-side pre-tensioner seat belt circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
1A, 1B
|
PS1_STAT
(Passenger-side air bag module circuit state)
|
SHRT GND/
SHRT B+/
OPEN/
SQ_LOWRES/
NORMAL
|
• Related wiring harness short to ground: SHRT GND
• Related wiring harness short to power supply: SHRT B+
• Related wiring harness circuit open: OPEN
• Pre-tensioner seat belt circuit resistance low: SQ_LOWRES
• Related wiring harness normal: NORMAL
|
2R, 2V
|
VBATT
(Battery voltage)
|
V
|
Under any condition: B+
|
2U
|