AUTO LEVELING SENSOR INSPECTION
id091800805600
1. Connect the three dry cell batteries (1.5 V) in series.
am2zzw00007223
|
2. Connect the positive pole of the battery to auto leveling sensor terminal A, and the negative pole to terminal C, then apply voltage of 4.5 V between terminals A and C.
3. Connect the tester as shown in the figure.
4. Measure the voltage while the link is moved up and down slowly.
Link angle (vehicle height) |
Voltage (V) |
---|---|
+45° (High)
|
Approx. 4.1
|
0°
|
2.25
|
-45° (Low)
|
Approx. 0.5
|