THERMOSTAT INSPECTION [ZJ, ZY]
id011219801300
1. Inspect the thermostat for the following.
Warning
• During inspection, the thermostat and water are extremely hot and can cause severe burns. Do not touch the thermostat and water.
• The valve should not open under normal temperature.
• Opening temperature and valve lift
― If there is a malfunction, replace the thermostat.
Thermostat initial-opening temperature
80—84 °C {176—183 °F}
Thermostat full-open temperature
95 °C {203 °F}
Thermostat full-open lift
More than 8.5 mm {0.33 in}