VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [ZJ, ZY]


id0113a8803100


Operation inspection

1.  Disconnect the negative battery cable.

2.  Remove the variable tumble shutter valve actuator.

3.  Connect the battery positive voltage to terminal A or B, and verify that the gear moves.

am2zzw00001400

•  If there is any malfunction, replace the variable tumble shutter valve actuator.

Terminal

Gear rotation direction

A

B

B+
Ground
Counterclockwise
Ground
B+
Clockwise