A/C CUT-OFF CONTROL OPERATION [ZJ, ZY]
id0140c4103700
Operation Condition
A/C cut-off control operation conditions
Operation condition |
A/C relay non-energization period |
Purpose |
---|---|---|
At engine start
|
Approx. 4 s
|
Improved startability
|
At drive-away
|
Approx. 3 s
|
Improved drive-away performance
|
During acceleration (throttle valve opening angle 50% or more)
|
Approx. 5 s
|
Improved acceleration performance
|
When engine coolant temperature is 113°C {235°F}
|
Repeatedly turns on and off every 10 s until the engine coolant temperature is less than approx. 107°C {225°F}
|
Improved engine reliability
|
Engine coolant temperature is 117°C {243°F} or more
|
Until engine coolant temperature is less than 110°C {230°F}
|
Improved engine reliability
|
At high engine speed
(engine speed 6,800 or more)
|
Until engine speed decreases to less than 6,300 rpm
|
Improved A/C compressor reliability
|
When temperature in PCM is 115°C {239°F} or more
|
Until temperature is PCM decreases to less than 112°C {234°F}
|
PCM protection
|
When evaporator temperature sensor is less than 3.7°C {39°F}*1
|
Until evaporator temperature sensor is 4.5°C {40°F} or more
|
To prevent blocking the air passing through evaporator due to freezing of dripping water.
|
• Brake pedal is depressed with all of the following conditions met
|
Approx. 2 s
|
Braking performance improvement
|