EGR CONTROL OPERATION [ZJ, ZY]
id0140c4171600
Stepping Motor Operation Principles
Energization condition for each coil
When current step number divided by eight |
Evenly divisible |
One leftover |
Two leftover |
Three leftover |
Four divisible |
Five leftover |
Six leftover |
Seven leftover |
---|---|---|---|---|---|---|---|---|
No.1 coil
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
No.2 coil
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
No.3 coil
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
No.4 coil
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
Example of energization condition for each coil and step number
Step number |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
30 |
52 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No.1 coil
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
No.2 coil
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
No.3 coil
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
OFF
|
ON
|
No.4 coil
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
OFF
|
Control outline
Target EGR valve position
Target EGR valve position determination table
Contents |
Method for calculating or determining the EGR valve position and correction |
|
---|---|---|
Basic EGR valve position
|
Within steps 0—52 in the stepping motor, determined as follows:
• When the engine speed is 1,187—4,200 rpm and the charging efficiency*1 is within 12.5—75%, the engine speed and charging efficiency are determined to be at basic position
• When the EGR control inhibition conditions are met, step 0.
|
|
correction*2
|
Engine coolant temperature correction
|
Purpose: Improved driveability
Engine coolant temperature is 65—75°C {149—167°F}
• The step number is restricted between 0—100% of the basic EGR valve position according to the engine coolant temperature.
(Low engine coolant temperature→low step number)
|
Intake air temperature correction
|
Purpose: Improved driveability
Intake air temperature is -5—0°C {23—32°F} or the intake air temperature is 60 °C {140°F} or more
• Step number is restricted between 40—100% of basic EGR valve position
(Low intake air temperature→large step number)
|
|
Acceleration/deceleration correction
|
Purpose: Improved driveability
During acceleration/deceleration, when the throttle valve opening angle fluctuation rate is the set value or more
• During acceleration→step number is restricted to 10% of basic EGR value position.
• During deceleration→step number is restricted to 0% of basic EGR valve position.
|
|
Variable tumble correction
|
Purpose: EGR volume optimization during variable tumble control
Controls EGR volume according to whether variable tumble shutter valve is open or closed
• Valve close→small correction
• Valve open→large correction
|
Inhibition conditions