KNOCK SENSOR (KS) INSPECTION [ZJ, ZY]


id0140c4802800


Resistance Inspection

1.  Disconnect the KS connector.

2.  Measure resistance between KS terminals A and body ground.

am2zzw00002585

•  If not as specified, replace the KS. (See KNOCK SENSOR (KS) REMOVAL/INSTALLATION [ZJ, ZY].)
Resistance
532—588 kilohms [20°C{68°F}]