EVAPORATOR TEMPERATURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]
id0740a2801200
1. Set the fan speed MAX HI.
2. Set the temperature control at MAX COLD (Turn the left).
3. Set the RECIRCULATE mode.
4. Turn the A/C switch off.
5. Close all doors and windows.
6. Wait for 5 min.
7. Disconnect the evaporator temperature sensor connector.
8. Measure the temperature at the blower inlet.
9. Measure the resistance between terminals of the evaporator temperature sensor.
am2zzw00001078
|