REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER]


id0740a2817300

1.  Disconnect the negative battery cable.

2.  Collect the refrigerant. (See REFRIGERANT CHARGING.)

3.  Remove the ground from the engine mount No.3.

am2zzw00003009

4.  Disconnect the refrigerant pressure sensor connector.

Caution
•  If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.

5.  Remove the cooler pipe. Do not allow compressor oil to spill.

6.  Loosen the refrigerant pressure sensor using two spanners.

7.  Remove the refrigerant pressure sensor. (See Refrigerant Pressure Sensor Installation Note.)

am2zzw00003190

Tightening torque
9—10 N·m {92—101 kgf·cm, 80—88 in·lbf}

8.  Install in the reverse order of removal.

9.  Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)


Refrigerant Pressure Sensor Installation Note

1.  Apply compressor oil to the O-rings and connect the joints.