INSTRUMENT CLUSTER CUSTOMIZED FUNCTION SETTING PROCEDURE
id092200555500
-
Note
-
• Use the IDS (laptop PC) because the PDS (pocket PC) does not support the customized functions setting procedure of the instrument cluster.
1. Connect the M-MDS to the DLC-2.
2. After vehicle identification, the following can be selected from the M-MDS initialization screen.
-
1. “Module Programming”
3. Then, select the following from the screen menu.
-
1. “Programmable Parameters”
2. “Warning Lamps/Chimes”
4. Select the following items and change the setting according to the directions on the screen.
-
Supported items
-
• DIS Correction (0%, 5%, 10%, 15%, -15%, -10%, -5%)
• Distance to Empty Response Data (1.50—5.25)
• Driver Beltminder Status (Disabled/Enabled)
• Passenger Beltminder Status (Disabled/Enabled)
-
Caution
-
• The M-MDS screen displays the following items, however, do not change the setting. If the setting is changed, a difference occurs between the instrument cluster indication and actual fuel level leading to unexpected fuel shortage.
-
― Fuel response data (level 1—16)