INSTRUMENT CLUSTER CUSTOMIZED FUNCTION SETTING PROCEDURE


id092200555500

Note
•  Use the IDS (laptop PC) because the PDS (pocket PC) does not support the customized functions setting procedure of the instrument cluster.

1.  Connect the M-MDS to the DLC-2.

am2zzw00002512

2.  After vehicle identification, the following can be selected from the M-MDS initialization screen.

1.  “Module Programming”

3.  Then, select the following from the screen menu.

1.  “Programmable Parameters”
2.  “Warning Lamps/Chimes”

4.  Select the following items and change the setting according to the directions on the screen.

Supported items
•  DIS Correction (0%, 5%, 10%, 15%, -15%, -10%, -5%)
•  Distance to Empty Response Data (1.50—5.25)
•  Driver Beltminder Status (Disabled/Enabled)
•  Passenger Beltminder Status (Disabled/Enabled)
Caution
•  The M-MDS screen displays the following items, however, do not change the setting. If the setting is changed, a difference occurs between the instrument cluster indication and actual fuel level leading to unexpected fuel shortage.
―  Fuel response data (level 1—16)