EVAPORATOR TEMPERATURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]
id0740a2801200
1. Switch the ignition OFF (LOCK).
2. Disconnect the negative battery terminal. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
3. Remove the following parts.
4. Connect the negative battery terminal. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
5. Perform the following procedure so that the ambient temperature of the evaporator temperature sensor is close to the cabin temperature.
6. Switch the ignition OFF (LOCK).
7. Disconnect the negative battery terminal. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
8. Disconnect the evaporator temperature sensor connector.
am2zzw00012294
|
9. Measure the temperature of the air intake port.
am2zzw00017287
|
10. Measure the resistance between the evaporator temperature sensor terminals A and B.
am3uuw00010229
|
am3uuw00004086
|