LDWS WARNING ALARM
id092200029600
Purpose
Function
am2zzn00002919
|
Construction
Operation
1. The instrument cluster receives (1) a warning sound request signal from the forward sensing camera (FSC) via CAN communication.
2. The instrument cluster turns the transistor on (2) based on the warning sound request signal.
3. When the transistor turns on, a ground circuit with the LDWS warning alarm is established and the LDWS warning alarm sounds (3).
am2zzn00002920
|
Fail-safe