4
|
Inspect the cooling fan control system operation.
Does the cooling fan control system work properly?
|
Yes
|
Access ECT PID.
Inspect both the ECT PID and temperature gauge in the instrument cluster readings.
• If the temperature gauge in the instrument cluster indicates a normal range but the ECT PID is not the same as the temperature gauge reading, inspect the ECT sensor.
• If the temperature gauge in the instrument cluster indicates a cold range but the ECT PID is normal, inspect the temperature gauge and the heat gauge units.
|
|
5
|
Verify the test results.
• If normal, return to the diagnostic index to service any additional symptoms.
• If the malfunction remains, inspect related Service information and perform repair or diagnosis.
-
- If the vehicle is repaired, the troubleshooting is completed.
-
- If the vehicle is not repaired or additional diagnostic information is not available, replace the PCM.
|