REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER]
id0740a2817300
1. Disconnect the negative battery cable.
2. Collect the refrigerant. (See REFRIGERANT CHARGING.)
3. Remove the ground from the engine mount No.3.
am2zzw00003009
|
4. Disconnect the refrigerant pressure sensor connector. (See Refrigerant Pressure Sensor Connector Removal Note.) (See Refrigerant Pressure Sensor Connector Installation Note.)
5. Remove the cooler pipe. Do not allow compressor oil to spill.
6. Loosen the refrigerant pressure sensor using two spanners.
7. Remove the refrigerant pressure sensor. (See Refrigerant Pressure Sensor Installation Note.)
am2zzw00003190
|
8. Install in the reverse order of removal.
9. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)
Refrigerant Pressure Sensor Connector Removal Note
1. Disconnect the refrigerant pressure sensor connector while pulling the tab.
am5ezw00006682
|
Refrigerant Pressure Sensor Connector Installation Note
1. When connecting the refrigerant pressure sensor connector, verify that the retainer is not removed from the connector.
am5ezw00006683
|
Retainer Installation Note
1. When newly replacing the retainer, remove the retainer from the purchased short wiring harness using a flathead screwdriver.
am5ezw00006684
|
2. Verify that the O-ring is installed.
am5ezw00006685
|
3. Install the retainer to the refrigerant pressure sensor connector.
Refrigerant Pressure Sensor Installation Note
1. Apply compressor oil to the O-rings and connect the joints.