OCV FOR HYDRAULIC VARIABLE VALVE TIMING SYSTEM INSPECTION
id011000566100
Coil Resistance Inspection
1. Measure the resistance between terminals A and B using an ohmmeter.
ac5wzw00010929
|
Spool Valve Operation Inspection
1. Verify that the spool valve in the OCV for hydraulic variable valve timing system is in the maximum valve timing advance position as indicated in the figure.
ac5wzw00003200
|
ac5wzw00010929
|
2. Apply battery positive voltage between the OCV for hydraulic variable valve timing system terminals and verify that the spool valve operates and moves to the maximum valve timing retard position.
ac5wzw00003201
|
3. Stop applying battery positive voltage and verify that the spool valve returns to the maximum valve timing advance position.