CURRENT SENSOR [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (E))]
id0140u1005000
Purpose/Function
• The battery conditions are monitored as basic information for determining the generator output current.
• The battery condition is input to the PCM via LIN communication.
Construction
• Installed to the negative battery cable.
• The current sensor has adopted shunt resistance on the detection area and a thermistor for detecting the battery condition.
Operation
• The battery charge/discharge flow, battery voltage, and the battery terminal temperature are input to the PCM by LIN communication.