COUPLING COMPONENT CALIBRATION DATA WRITING


id031900806200

Caution
•  If the characteristic value of a new coupling component is not input to the PCM or the characteristic value is input incorrectly after replacing the coupling component, it could result in the following conditions.
―  The system does not operate normally.
―  A problem with durability of the coupling component occurs.
Note
•  The Writing the characteristic value of coupling can be performed using the M-MDS.
•  After replacing the coupling component, read out the characteristic value of a new coupling component and write it to the PCM.
•  Read out the characteristic value of the coupling component from the label or mark shown in the figure.
am3zzw00038526

1.  Connect the M-MDS to the DLC-2.

2.  Perform the following procedure using the M-MDS.

(1)  Press [Start] for the vehicle identification.
(2)  Press the [Toolbox] tab.
(3)  Press the [Work Support] icon.
(4)  Press [TRANSMISSION/TRANSAXLE].
(5)  Press [Run] for Writing the characteristic value of Coupling.

3.  Input the 24-digit coupling component characteristic value in 2 lines (12 digits per line) according to the directions on the screen.

4.  Press [Run] for Reading the characteristic value of Coupling.

5.  Perform the Coupling calibration data reading according to the directions on the screen.