COUPLING COMPONENT CALIBRATION DATA WRITING
id031900806200
-
Caution
-
• If the characteristic value of a new coupling component is not input to the PCM or the characteristic value is input incorrectly after replacing the coupling component, it could result in the following conditions.
-
― The system does not operate normally.
― A problem with durability of the coupling component occurs.
-
Note
-
• The Writing the characteristic value of coupling can be performed using the M-MDS.
• After replacing the coupling component, read out the characteristic value of a new coupling component and write it to the PCM.
• Read out the characteristic value of the coupling component from the label or mark shown in the figure.
1. Connect the M-MDS to the DLC-2.
2. Perform the following procedure using the M-MDS.
- (1) Press [Start] for the vehicle identification.
-
- (2) Press the [Toolbox] tab.
-
- (3) Press the [Work Support] icon.
-
- (4) Press [TRANSMISSION/TRANSAXLE].
-
- (5) Press [Run] for Writing the characteristic value of Coupling.
-
3. Input the 24-digit coupling component characteristic value in 2 lines (12 digits per line) according to the directions on the screen.
4. Press [Run] for Reading the characteristic value of Coupling.
5. Perform the Coupling calibration data reading according to the directions on the screen.