VARIABLE VALVE TIMING ACTUATOR INSPECTION [LF, L5]
id0110a7801200
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [LF, L5].)
2. Disconnect the negative battery cable.
3. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [LF, L5].)
4. Disconnect the wiring harness.
5. Remove the ignition coils. (See IGNITION COIL REMOVAL/INSTALLATION [LF, L5].)
6. Remove the spark plugs. (See SPARK PLUG REMOVAL/INSTALLATION [LF, L5].)
7. Remove the ventilation hose.
8. Remove the dipstick.
9. Remove the cylinder head cover. (See TIMING CHAIN REMOVAL/INSTALLATION [LF, L5].)
10. Confirm that notch of the rotor and notch of the cover at the variable valve timing actuator are aligned and fitted.
am6xuw00002472
|