Engine Tune-up Preparation
1. Verify the following:
2. Warm up the engine to normal operating temperature.
3. Turn off all electrical loads.
4. Connect the M-MDS to the DLC-2.
am3zzw00006882
|
Idle Speed Inspection
1. Complete the engine tune-up preparation. (See Engine Tune-up Preparation.)
2. Verify that the idle speed (M-MDS: RPM PID) is within the specification.
Ignition Timing Inspection
1. Complete the engine tune-up preparation. (See Engine Tune-up Preparation.)
2. Verify the ignition timing (M-MDS: SPARKADV) using the PID/data monitor function of the M-MDS.
3. Verify that ignition timing advances when the engine speed increases gradually.
Idle Mixture Inspection
1. Verify that the shift lever is in neutral position.
2. Warm up the engine to normal operating temperature.
3. Insert an exhaust gas analyzer into the tailpipe.
4. Verify that the CO and HC concentrations are within regulation.
Idle-up Speed Control Inspection
1. Complete the engine tune-up preparation. (See Engine Tune-up Preparation.)
2. Verify that the engine speed (M-MDS: RPM PID) is within the specification when each load is applied. (The speed decrease just after the load is applied is not considered.)
Idle-up speed (European (L.H.D. U.K.) specs. (Except for Israel) and Saudi Arabia)
Load status (ATX: P, N position, MTX: Neutral position) |
Idle speed (rpm) |
||
---|---|---|---|
A/C on (With A/C)
|
Refrigerant pressure switch (middle pressure) is on
|
ATX
|
700—800
|
MTX
|
700—800
|
||
Refrigerant pressure switch (middle pressure) is off
|
ATX
|
700—800
|
|
MTX
|
650—750
|
||
Electrical loads on
|
ATX
|
700—800
|
|
MTX
|
650—800
|
Idle-up speed (Israel)
Load status (ATX: P, N position) |
Idle speed (rpm) |
||
---|---|---|---|
A/C on (With A/C)
|
Refrigerant pressure switch (middle pressure) is on
|
770—870
|
|
Refrigerant pressure switch (middle pressure) is off
|
700—800
|
||
Electrical loads on
|
650—770
|
Idle-up speed (General (L.H.D. R.H.D.) specs. (Except for Saudi Arabia)) [ATX, MTX]
Load status (ATX: P, N position, MTX: Neutral position) |
Idle speed (rpm) |
||
---|---|---|---|
A/C on (With A/C)
|
Refrigerant pressure switch (middle pressure) is on
|
ATX
|
700—800
|
MTX
|
700—800
|
||
Refrigerant pressure switch (middle pressure) is off
|
ATX
|
700—800
|
|
MTX
|
650—750
|
||
Electrical loads on
|
ATX
|
700—800
|
|
MTX
|
650—800
|
Idle-up speed (General (R.H.D.) specs.) [CVT]
Load status (CVT: P, N position) |
Idle speed (rpm) |
||
---|---|---|---|
A/C on (With A/C)
|
Refrigerant pressure switch (middle pressure) is on
|
700—800
|
|
Refrigerant pressure switch (middle pressure) is off
|
600—700
|
||
Electrical loads on
|
550—800
|