COOLING SYSTEM CAP, COOLANT RESERVE TANK CONSTRUCTION [MZR 2.0 DISI i-stop]


id011237142100

•  A low-pressure type cap has been adopted for the cooling system. It is installed on the coolant reserve tank to improve serviceability when adding engine coolant and bleeding air.
•  A degassing type coolant reserve tank has been adopted to integrate the simple airtight sub-tank and the air/water separating tank, improving the air/water separating function. The integrated and large-size degassing tank consists of a labyrinth structure with internal barriers to lengthen the distance to the outlet and reduce the flow speed. This lengthens the time the engine coolant has to accumulate, improving the air/water separation function.
am3zzn00002221