COOLING FAN MOTOR INSPECTION [ZY, Z6]


id0112a0801800


Part Inspection

1.  Verify that the battery is fully charged. (See BATTERY INSPECTION [ZY, Z6].)

2.  Disconnect the cooling fan motor connector (2 terminals).

3.  Install a tester and battery to the cooling fan motor connector (2 terminals) as shown in the figure.

am3zzw00006384

4.  Verify that each cooling fan motor operates smoothly at the standard current.

•  If there is any malfunction, replace the applicable part.
Cooling fan motor standard current [12 V]
No.1: 3.7—6.7 A
No.2: 6.1—9.1 A