VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [LF, L5]
id0113a4803100
Operation Inspection
1. Remove the air hose. (See INTAKE MANIFOLD VACUUM INSPECTION [LF, L5].)
2. Disconnect the vacuum hose from the variable tumble shutter valve actuator.
am6zzw00000220
|
3. Connect a vacuum pump to the variable tumble shutter valve actuator.
4. Check if the rod operates correctly as stated in the table when a gradual negative pressure is applied to the variable tumble shutter valve actuator.
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –2.7 {–20, –0.8}
|
No operate
|
Above –33.4 {–251, –9.86}
|
Fully pulled
|