VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [ZY, Z6]
id0113b0803100
Operation inspection
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [ZY, Z6].)
2. Disconnect the negative battery cable.
3. Remove the variable tumble shutter valve actuator. (See VARIABLE TUMBLE SHUTTER VALVE ACTUATOR REMOVAL/INSTALLATION [ZY, Z6].)
4. Connect the battery positive voltage to terminal A or B, and verify that the gear moves.
am3zzw00005116
|
Terminal |
Gear rotation direction |
|
---|---|---|
A |
B |
|
B+
|
Ground
|
Clockwise
|
Ground
|
B+
|
Counterclockwise
|