VARIABLE INTAKE AIR SOLENOID VALVE CONSTRUCTION/OPERATION [MZR 2.0 DISI i-stop]


id0113b8147900


Construction

•  Mainly composed of the coil, spring, and plunger.

Operation

Energized
•  The coil magnetizes, pulling the plunger. The passage between A and B ports opens due to the plunger being pulled, and intake manifold vacuum is applied to the variable intake air shutter valve actuator.
De-energized
•  The intake manifold vacuum passage is blocked, and the passage between ports B and C opens, depressurizing the variable intake air shutter valve actuator.