FUEL PUMP UNIT INSPECTION [ZY, Z6]
id0114b0801100
Continuity Inspection
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [ZY, Z6].)
2. Disconnect the negative battery cable.
3. Disconnect the fuel pump unit connector.
4. Inspect for continuity between fuel pump unit terminals A—E.
am3uuw00003287
|