FUEL TANK INSPECTION [ZY, Z6]
id0114b0803200
1. Complete the “BEFORE SERVICE PRECAUTION”. (See BEFORE SERVICE PRECAUTION [ZY, Z6].)
2. Remove the fuel tank and the fuel pump unit as a single unit. (See FUEL TANK REMOVAL/INSTALLATION [ZY, Z6].)
3. Perform the following procedure to verify the fuel tank airtightness.
am3zzw00005132
|
4. Plug the fuel pump unit pipe and port B.
am3zzw00005133
|
5. Level the fuel tank.
6. Apply a pressure of 3 kPa {23 mmHg, 0.9 inHg} to port A and wait for a while.
7. With the pressure still applied, verify that there is air flow port C and the pressure is 0—3 kPa {0—23 mmHg, 0—0.9 inHg}.
8. Apply a pressure of -0.5 kPa {-3.8 mmHg, -0.1 inHg} to port A and wait for a while.
9. With the pressure still applied, verify that there is air flow port C and the pressure is -0.5—0 kPa {-3.8—0 mmHg, -0.1—0 inHg}.
10. Apply a pressure to port A and wait for a while.
am3zzw00005134
|
11. With the pressure still applied, verify that there is no air flow from port C.