AFTER SERVICE PRECAUTION [MZ-CD 1.6 (Y6)]
id0114c3801900
Fuel Line Air Bleeding
1. Disconnect the fuel return hose.
2. Connect the SST.
EURO4 emission level
am3zzw00008086
|
EURO5 emission level
am3zzw00012507
|
3. Operate the hand pump unit until it becomes firm when squeezed.
4. Squeeze and hold the hand pump for 10.
5. Release the hand pump.
6. Squeeze and hold the hand pump for a further 10.
7. Release the hand pump.
8. Disconnect the SST.
9. Connect the fuel return hose.
10. Start the engine and allow it to idle until it reaches normal operating temperature.
11. Turn the engine switch off.